Diagnostic

Error

Code

FRU/Action

001-026-XXX

System

FLASH

data

error

1.

Flash

the

system

2.

System

board

001-027-XXX

System

Configuration/Setup

error

1.

Run

Setup

2.

Flash

the

system

3.

System

board

001-032-XXX

System

Device

Controller

failure

System

board

001-034-XXX

System

Device

Buffer

Allocation

failure

1.

Reboot

the

system

2.

Flash

the

system

3.

Run

memory

test

4.

System

board

001-035-XXX

System

Device

Reset

condition

detected

System

board

001-036-XXX

System

Register

error

System

board

001-038-XXX

System

Extension

failure

1.

Adapter

card

2.

System

board

001-039-XXX

System

DMI

data

structure

error

1.

Flash

the

system

2.

System

board

001-040-XXX

System

IRQ

failure

1.

Power-off/on

system

and

re-test

2.

System

board

001-041-XXX

System

DMA

failure

1.

Power-off/on

system

and

re-test

2.

System

board

001-195-XXX

System

Test

aborted

by

user

1.

Information

2.

Re-start

the

test,

if

necessary

001-196-XXX

System

test

halt,

error

threshold

exceeded

1.

Press

F3

to

review

the

log

file

2.

Re-start

the

test

to

reset

the

log

file

001-197-XXX

System

test

warning

1.

Make

sure

the

component

that

is

called

out

is

connected

and/or

enabled

2.

Re-run

test

3.

Component

that

is

called

out

in

warning

statement

4.

Component

under

test

001-198-XXX

System

test

aborted

1.

If

a

component

is

called

out,

make

sure

it

is

connected

and/or

enabled

2.

Flash

the

system

and

re-test

3.

Go

to

“Undetermined

problems”

on

page

109

001-199-XXX

System

test

failed,

cause

unknown

1.

Go

to

“Undetermined

problems”

on

page

109

2.

Flash

the

system

and

re-test

3.

Replace

component

under

function

test

001-250-XXX

System

ECC

error

1.

System

board

72

Hardware

Maintenance

Manual