IBM THINKCENTER 8189 User Manual

Page 79

Advertising
background image

Diagnostic

Error

Code

FRU/Action

001-254-XXX

001-255-XXX

001-256-XXX

001-257-XXX

System

DMA

error

System

board

001-260-XXX

001-264-XXX

System

IRQ

error

System

board

001-268-XXX

System

IRQ1

failure

1.

Device

on

IRQ1

2.

System

board

001-269-XXX

System

IRQ2

failure

1.

Device

on

IRQ2

2.

System

board

001-270-XXX

System

IRQ3

failure

1.

Device

on

IRQ3

2.

System

board

001-271-XXX

System

IRQ4

failure

1.

Device

on

IRQ4

2.

System

board

001-272-XXX

System

IRQ5

failure

1.

Device

on

IRQ5

2.

System

board

001-273-XXX

System

IRQ6

(diskette

drive)

failure

1.

Diskette

Cable

2.

Diskette

drive

3.

System

board

001-274-XXX

System

IRQ7

failure

1.

Device

on

IRQ7

2.

System

board

001-275-XXX

System

IRQ8

failure

1.

Device

on

IRQ8

2.

System

board

001-276-XXX

System

IRQ9

failure

1.

Device

on

IRQ9

2.

System

board

001-277-XXX

System

IRQ10

failure

1.

Device

on

IRQ10

2.

System

board

001-278-XXX

System

IRQ11

failure

1.

Device

on

IRQ11

2.

System

board

001-279-XXX

System

IRQ12

failure

1.

Device

on

IRQ12

2.

System

board

001-280-XXX

System

IRQ13

failure

1.

Device

on

IRQ13

2.

System

board

001-281-XXX

System

IRQ14

(hard

disk

drive)

failure

1.

Hard

disk

drive

cable

2.

Hard

disk

drive

3.

System

board

001-282-XXX

System

IRQ15

failure

1.

Device

on

IRQ15

2.

System

board

Chapter

7.

Symptom-to-FRU

Index

73

Advertising