IBM THINKCENTER 8189 User Manual

Page 82

Advertising
background image

Diagnostic

Error

Code

FRU/Action

006-198-XXX

Diskette

interface

test

aborted

1.

If

a

component

is

called

out,

make

sure

it

is

connected

and/or

enabled

2.

Flash

the

system

and

re-test

3.

Go

to

“Undetermined

problems”

on

page

109

006-199-XXX

Diskette

interface

test

failed,

cause

unknown

1.

Go

to

“Undetermined

problems”

on

page

109

2.

Flash

the

system

and

re-test

3.

Replace

component

under

function

test

006-25X-XXX

Diskette

interface

Error

1.

Diskette

drive

cable

2.

Diskette

drive

3.

System

board

011-000-XXX

Serial

port

Interface

Test

Passed

1.

No

action

011-001-XXX

Serial

port

Presence

1.

Remove

external

serial

device,

if

present

2.

Run

setup,

enable

port

3.

System

board

011-002-XXX

011-003-XXX

Serial

port

Timeout/Parity

error

System

board

011-013-XXX

011-014-XXX

Serial

port

Control

Signal/Loopback

test

failure

System

board

011-015-XXX

Serial

port

External

Loopback

failure

1.

Wrap

plug

2.

System

board

011-027-XXX

Serial

port

Configuration/Setup

error

1.

Run

Setup,

enable

port

2.

Flash

the

system

3.

System

board

011-03X-XXX

011-04X-XXX

Serial

port

failure

System

board

011-195-XXX

Serial

port

Test

aborted

by

user

1.

Information

2.

Re-start

the

test,

if

necessary

011-196-XXX

Serial

port

test

halt,

error

threshold

exceeded

1.

Press

F3

to

review

the

log

file

2.

Re-start

the

test

to

reset

the

log

file

011-197-XXX

Serial

port

test

warning

1.

Make

sure

the

component

that

is

called

out

is

connected

and/or

enabled

2.

Re-run

test

3.

Component

that

is

called

out

in

warning

statement

4.

Component

under

test

76

Hardware

Maintenance

Manual

Advertising