Diagnostic

Error

Code

FRU/Action

175-000-XXX

Thermal

Sensor(s)

Test

Passed

No

action

175-0XX-XXX

Thermal

Sensor(s)

failure

1.

Flash

system

2.

System

board

175-195-XXX

Thermal

Sensor(s)

Test

aborted

by

user

1.

Information

2.

Re-start

the

test,

if

necessary

175-196-XXX

Thermal

Sensor(s)

test

halt,

error

threshold

exceeded

1.

Press

F3

to

review

the

log

file

2.

Re-start

the

test

to

reset

the

log

file

175-197-XXX

Thermal

Sensor(s)

test

warning

1.

Make

sure

the

component

that

is

called

out

is

connected

and/or

enabled

2.

Re-run

test

3.

Component

that

is

called

out

in

warning

statement

4.

Component

under

test

175-198-XXX

Thermal

Sensor(s)

test

aborted

1.

If

a

component

is

called

out,

make

sure

it

is

connected

and/or

enabled

2.

Flash

the

system

and

re-test

3.

Go

to

“Undetermined

problems”

on

page

109

175-199-XXX

Thermal

Sensor(s)

test

failed,

cause

unknown

1.

Go

to

“Undetermined

problems”

on

page

109

2.

Flash

the

system

and

re-test

3.

Replace

component

under

function

test

175-250-XXX

175-251-XXX

Thermal

Sensor(s)

limit

error

1.

Check

fans

2.

Check

Power

supply

3.

Microprocessor

4.

System

board

185-000-XXX

Asset

Security

Test

Passed

No

action

185-XXX-XXX

Asset

Security

failure

1.

Flash

system

2.

System

board

185-278-XXX

Asset

Security

Chassis

Intrusion

1.

Assure

Asset

Security

Enabled

2.

C2

Cover

Switch

3.

System

board

201-000-XXX

System

Memory

Test

Passed

No

action

201-XXX-XXX

System

Memory

error

1.

Replace

the

memory

module

called

out

by

the

test

2.

System

board

202-000-XXX

System

Cache

Test

Passed

No

action

202-XXX-XXX

System

Cache

error

1.

Cache,

if

removable

2.

System

board

3.

Microprocessor

86

Hardware

Maintenance

Manual