Connecting to the line through an external csu – Interphase Tech iSPAN 5535 PRI User Manual

Page 40

Advertising
background image

North America T1/PRI Line

20

Interphase Corporation

W

ARNING

To avoid harming the WAN, you must first contact your
carrier for approval before connecting the adapter to the
line.

C

AUTION

In accordance with FCC Rules, Part 68.218 (b), you must
notify the telephone company prior to disconnecting
the
adapter from the line or turning off the power to the
adapter’s host system. Without this prior notification, the
carrier might temporarily discontinue your T1/PRI service.

Connecting to the line through an external
CSU

If the distance to your carrier is longer than 655 feet (200
meters), or if your carrier does not accept a direction DSX1
connection, and if your iSPAN-PRI adapter does not include
an internal Channel Service Unit (CSU), you need to connect
an external CSU between the adapter and the network.