E1 link requirements, Connector pinouts – Interphase Tech iSPAN 5535 PRI User Manual

Page 44

Advertising
background image

Connector Pinouts

24

Interphase Corporation

The cable must include an RJ48C plug at the end dedicated to
the WAN adapter. It must also provide the appropriate plug or
cabling system at the end dedicated to the NT1. See Connector
Pinouts
on page 24
and your NT1 documentation for details.

E1 Link Requirements

To interoperate successfully, the adapter and the NT1 must be
configured with several common E1 settings. The adapter’s E1
parameters are in accordance with the IUT-T I 431
recommendation, as follows:

• Line

coding: HDB3, according to IUT-T G.703

• Frame

format: according to IUT-T G.704

• CRC4 to Non-CRC4 operation: according to

IUT-T G.706 An.B

• Line I/O impedance: 120 Ohm

± 5%.

Connector Pinouts

The following illustration of the adapter’s faceplate shows the
adapter’s connectors and connector pins: