European E1/PRI Line

When you connect the adapter to a European E1/PRI line, first
determine the appropriate connection method, cabling
requirements, and link requirements.

This section describes the method and requirements for
connecting the adapter to a European E1/PRI line.

Connection Method

Generally, your E1/PRI carrier provides a Network
Termination 1 (NT1) device to interface between the WAN
adapter and the metallic interface of the WAN. You need to
connect the WAN adapter to the NT1.

E1/PRI Cabling Requirements

W

ARNING

Before connecting the cable, read Telephone Lines
Unsafe Voltages
in the Safety Precautions section at the
front of this manual.

The cable between the adapter and the NT1 must meet the
following standard E1 attenuation and transmission
requirements:

120 Ohm

two twisted pairs, category 3 or better

maximum length: 200 m (655 feet)