JAI TM-2016-8/8CL User Manual

Page 35

Advertising
background image

Page 25

TM-2016-8 and TM-2016-8CL Progressive Scan Shutter Camera

Operation

Model: TM-2016-8

Operation Mode: 8 Frames/Second

Master Clock: 40.0 MHz, M= 25.0 nsec
Pixel Clock: 20.0 MHz, P= 50.0 nsec

3. External Reset Timing

4. Async Reset Timing

External VD

Internal VD

FDV

Digital Data

Analog Video

VINIT Trigger

Internal VD

FDV

Digital Data

Analog Video

Horizontal Frequency: 9.09 KHz
1H = 110 sec

A [ 1125 H], (123.75 msec)

B [7 P], ( 350 ns)

C [ 9 H], ( 990 us)

D [ 1116 H], ( 122.76 ms)

E [ 1125 H], ( 123.75 ms)

J [3 H], ( 330 s)

N [ 3 H], ( 330 s)

F [ 45 H], ( 4.95ms)

H [ 45 H], ( 4.95 ms)

K [ 42 H], ( 4.62 ms)

L [ 3 H], ( 330 s)

G [ 1080 H], ( 118.80 ms)

I [ 1080 H], ( 118.80 ms)

M [ 1080 H], (118.80 ms)

Q [ 1116 H], ( 122.76 ms)

R [ 1125 H], ( 123.75 ms)

U [ 1080 H], ( 118.80 ms)

Y [1080 H], ( 118.80ms)

O [7 P], ( 350 ns)

V [ 42 H], (4.62 ms)

T [45 H], ( 4.95 ms)

X [ 3 H], ( 330s)

Z [ 3H], ( 330 s)

W [3 H], ( 330 s)

P [9 H], ( 990 us)

S [ 45 H], ( 4.95 ms)

Q: Internal VD shift = 1H + async shutter speed

Advertising