Chapter 1 Getting Started

Using Commands to Control Key Functions (Examples)

User’s Guide

1-13

To Check the Input Channel Automatic Switching Status

Enter INP:SEL:AUTO?, and press Return.

If 0 is returned, automatic switching is disabled. If 1 is returned,
automatic switching is enabled.

To Enable the Input Channel Automatic Switching

Enter INP:SEL:AUTO 1, and press Return.

To Disable the Input Channel Automatic Switching

Enter INP:SEL:AUTO 0, and press Return.

Distributing Input A and Backup Oscillator (Option 010)
Signals

To Check the Input A Channel Signal Status

Enter INP:A:QUES?, and press Return.

If 0 is returned, input signal is present. If 1 is returned, input signal is
absent.

To Verify that the Internal Oscillator (Option 010) is Producing 10 MHz

Enter ROSC:QUES?, and press Return.

If 0 is returned, oscillator output is normal. If 1 is returned, oscillator
output is questionable.

To Check the Input Channel Automatic Switching Status

Enter INP:SEL:AUTO?, and press Return.

If 0 is returned, automatic switching is disabled. If 1 is returned,
automatic switching is enabled.

To Enable the Input Channel Automatic Switching

Enter INP:SEL:AUTO 1, and press Return.

To Disable the Input Channel Automatic Switching

Enter INP:SEL:AUTO 0, and press Return.