58502A Command Summary

User’s Guide

4-5

Table 4-1. 58502A Command

Summary

(Continued)

Keyword/Syntax

Parameters

Description

INPut (Continued)

INPUT Subsystem (Continued)

:AUTO

:AUTO?

append 0 or OFF, or

1 or ON

returns 0 or 1

Enables or disables the automatic input switching feature. 0 or
OFF disables it while 1 or ON enables it. This setting is stored
in non-volatile memory.
Query.

:DEFault

:DEFault?

A or B

returns A or B

Selects the default input channel (or port) to be used at
powerup. This setting has no impact on auto-switching and
does not affect the current input channel selection. This setting
is stored in non-volatile memory.
Query.

OUTPut:QUEStionable

OUTPut:QUEStionable Subsystem

:PACKed?

returns binary
weighted decimal

Provides status on each output in a single packed integer.
Each bit is associated with an output channel. The least
significant bit = output 1, next bit = output 2, and so on. If bit is
0, output signal is present. Hence value of 0 indicates that all
outputs are outputting the source signal. If there was no output
from outputs 2 and 3, the response would be:
6 (1*0 + 2*1 + 4*1 + 8*0 + ... = 6)

[:UNPacked]?

returns array of
Boolean

Provides status on each output (lowest numbered output to
highest). 0 = signal at output, 1 = no signal at output. Same
result as PACKed? (see prior command), but information on
each output is provided with separate value. If outputs 3 and 5
were not outputting the source signal, the response would be:
0,0,1,0,1,0,0,0,0,0,0,0

[SOURce]:ROSCillator

ROSCillator Subsystem (USED WITH OPTION 010 ONLY)

:WARM?

0 or 1

Reports if internal oscillator is warmed up.
0 = not warm.
1 = warm.

SYSTem

SYSTem Subsystem

:COMMunicate:SERial

Node Only

:FDUPlex

0 or 1

Sets duplex. (0 = echo Off, 1 = echo On).

[:RECeive] | TRANsmit

Node Only. There is a single setting of commands under this
node for both transmit and receive. Default values are in italics.

:BAUD

<numeric>

Sets the BAUD rate (1200, 2400, 9600, 19200).

:BITS?

7 or 8

Returns Data Bits set by PARity (7 for odd/even, 8 for none).

:PACE

XON | NONE

Sets flow control. (On or None).

:PARity

Node Only.

[:TYPE]

EVEN | ODD |
NONE

Sets parity. (Odd, Even, or None).

:ERRor?

returns integer,
quoted string

First parameter is error number, quoted string is error
description.