7 rs485 setup, 1 unit id, 2 baud rate – Speco Technologies DVR-16TT User Manual

Page 75: Ddns port, Submit/update, Rs485 setup, Unit id, Baud rate

Advertising
background image

User’s Manual

DVR-4TN/8TN/16TN/16TS/16TT Series

SPECO TECHNOLOGIES 01/06

74

NOTE:

No any two DVR-4TN/ DVR-8TN/ DVR-16TN series units

should be set the same Host Name.

-

DDNS Port

This item allows the user to setup the port for DDNS. Press UP / DOWN
Direction keys to change the port.

-

Submit/Update

When done, move the cursor to this item and press ENTER to submit the
settings.

NOTE:

If there are two DVR-4TN/ DVR-8TN/ DVR-16TN series units

set with the same domain name, the later setting will not be submit

successfully.

5.1.7

RS485 Setup

This menu allows the user to setup the parameters of the unit’s RS-485
communications port. From the Main menu, select <RS485 Setup> and press
ENTER. The following menu is displayed.

RS485 Setup

1. Unit ID
2. Baud Rate
3. Bits
4. Stop
5. Parity

224

9600

8
1

None

5.1.7.1 Unit ID

This item is used to change the RS-485 ID address of the unit. The ID is with
the range of <1> to <255>. The default is <224>.

5.1.7.2 Baud Rate

The Baud rate options for association with the protocol are <2400>, <4800>,
<9600>, <19200>, <38400> and <57600>. The default is <9600> baud.