3.12.2

Ramp-function generator (RFG)

Parameter range:

P1120, P1121

r1119, r1170

P1130 – P1142

Warnings -
Faults -

Function chart number:

FP5000, FP5300

The ramp-function generator is used to limit the acceleration when the setpoint
changes according to a step function. This therefore helps to reduce the stressing
on the mechanical system of the machine. An acceleration ramp and a braking
ramp can be set independently of one another using the ramp-up time P1120 and
the ramp-down time P1121. This allows a controlled transition when the setpoint is
changed (refer to Fig. 3-42).