1 general, 2 ambient operating conditions, Installation after a period of storage – Siemens MICROMASTER 420 User Manual

Page 23: Temperature

Advertising
background image

Issue 07/04

2 Installation

MICROMASTER 420 Operating Instructions

6SE6400-5AA00-0BP0

23

2.1 General

Installation after a Period of Storage

Following a prolonged period of storage, you must reform the capacitors in the
inverter. The requirements are listed below.

Storage period less than 1 year:

No action necessary

Storage period 1 to 2 years

Prior to energizing, connect to
voltage for one hour

Storage period 2 to 3 years

Prior to energizing, form
according to the curve

Storage period 3 and more years

Prior to energizing, form
according to the curve

100

50

75

0,5

1

Voltage

[%]

Time t [h]

2

4

6

8

Fig. 2-1

Forming

2.2

Ambient operating conditions

Temperature

0

20

30

10

40

[°C]

Operating temperature

-10

50

60

75

50

25

100

[%]

Permissible output current

Fig. 2-2

Ambient operating temperature