11 the status of indicator in outdoor unit – Soleus Air KFHHP-22 User Manual

Page 13

Advertising
background image

6.1.3.11 The status of indicator in outdoor unit

Notice: When the unit is power-on again, the times of all the protection above (including: overloading protection, high

exhausting gas temp. protection of compressor, overcurrent protection, module protection etc.) will be reset.

D11

Meaning

D12

Meaning

D13

Meaning

blink 1 time

compressor starts to run

blink 1 time

cooling

overload

protection stop

blink 1 time

quick cooling/heating

blink 2 times

exhaust protection stop

blink 2 times

heating

overload

protection stop

blink 2 times

defrosting

blink 3 times

closing down for NEC

driving module protection

blink 3 times

communication

failure

with indoor unit

blink 3 times

oil returning

blink 4 times

closing down for

overcurrent protection

blink 4 times

communication failure with

NEC module

blink 4 times

nominal

cooling/heating

blink 5 times

closing down for

overloading protection

blink 5 times

communication failure with

computer

blink 5 times

max. cooling/heating

blink 6 times

cooling antifreezing stop

blink 6 times

failulre of outdoor ambient

temp.sensor

blink 6 times

medial cooling/heating

blink 7 times

sensor malfunction stop

blink 7 times

failure

of

outdoor

tube-temp.sensor

blink 7 times

min.cooling/heating

blink 8 times

closing down for

communication

failure(including indoor

unit and NEC driving

module)

blink 8 times

failure

of

outdoor

gas-discharge

temp.sensor

blink 8 times

unit off

blink 12 times

closing down for IPM

overheating protection

blink 9 times

communication

failure

sent from indoor

blink 9 times

low pressure and can’t

resume

blink 10

times

wrong parameters sent to

NEC driver, unit closes

down

blink 11

times

IPM temp. sensor failure

D14

meaning

D15

meaning

D16

meaning

blink 1 time

frequency demultiplying

for high temp.of gas

discharged

blink 1 time

frequency limiting for high

temp.of gas discharged

on

Be receiving or sending

computer data

blink 2 times

frequency demultiplying

for overcurrent protection

blink 2 times

frequency

limiting

of

overcurrent protection

off

receiving

or

sending

computer data finished

blink 3 times

frequency demultiplying

for cooling overload

blink 3 times

frequency

limiting

for

cooling overloading

blink 4 times

frequency demultiplying

for heating overload

blink 4 times

frequency

limiting

for

heating overloading

blink 5 times

frequency demultiplying

for frost-proof

blink 5 times

frequency of current 9.4 A

lasting for 2 minutes

-13-