Soleus Air KFHHP-22 User Manual

Page 22

Advertising
background image

Disassemble compressor

Unsolder the soldering points between the pipes and compressor;unscrew

the three nuts with washers at the foot of compressor;take out the compressor

compressor

(Refer to figure 7-25)

Figure

compressor nuts

Disassemble valves

Unsrew the two screws fixing the big valve;unsoldering the soldering

points between the big valve and air-return duct;remove big valve

(When unsoldering,use wet cloth to wrap the big valve completely

to prevent it from being harmed by high temperature.

Unscrew the 2 screws fixing small valve;unsolder the joint points

between small valve and fork type pipe;remove small valve

(Refer to figure 7-24)

small valve

screws

big valve

Disassemblle capillary

Unsolder the joint points between capillary and other pipelines;them it
can be removed

(Refer to figure 7-23)

capillary

Operating procedures/pictures

-2

2-

Advertising