Troubleshooting – Soleus Air KFHHP-22 User Manual

Page 27

Advertising
background image

9

Troubleshooting

Analysis in this section is used for D.C. Variable Frequency Series. Before analysis, you can diagnose
according to the code displayed on indoor unit or indicator display on outdoor unit. (Refer to Malfunction
display section).

Air
conditi
oner
cannot
start up

Breaker tripped
or fuse burnt out

Air conditioner

does not response

after powered on.

(The buzzer does

not sound after the

plug is connected

and the unit does

not response after

the remote

controller is used

to turn it on)

When the breaker is set ON, it will
trip at once

Remote
controller does
not receive signal
(When powered
on, the buzzer
will send out a
sound, unless it is
broken)

When the unit is turned on, the
breaker will trip in a few minutes

No power supply

The power plug is not or poorly

connected

Controller fuse is burnt out

Loose or poor contact of transformer
connection, or transformer malfunction

The controller is broken

Batteries of remote controller are low

Malfunction of remote controller

Loose or poor connection of receiving

head

Receiving head is broken

Measure the insulating resistance

for grounding to confirm whether

there is electrical leakage or short

circuit in the unit

Insulation malfunction of line or componen
in the air conditioner. Insulation breakdow
occurs after radiation, which causes shor
circuit or electricity leakage. Measure
insulating resistance or use one-by-on
elimination method;
Malfunction of fuse. Replace it.

Check power supply circuit

Check and plug well plug, make
loosen contact firm

Change control fuse

Secure the wire connection: measure
the output voltage of the transformer
and replace it if the value is wrong

Replace the controller

Change battery

First press the "AUTO" button of the
manual switch. If there is no response,
check according to the above method;
if it is normal after the button is
pressed, check if the installation
location and wire connection of the
receiving head are correct. If correct,
replace the receiving head, or the
remote controller.

-2