Soleus Air KFHHP-22 User Manual

Page 14

Advertising
background image

D14

Meaning

D15

Meaning

blink 6 times

Unit closing down for

min.frequency

blink 6 times

frequency of current 12 A lasting for 2 minutes

blink 7 times

Unit closing down for

PFC protection

blink 7 times

frequency limiting or demultiplying for rate of

frequency variation out of control

blink 8 times

Unit closing down for

compressor overloading

blink 8 times

frequency limiting or demultiplying of compressor

current

blink 9 times

frequency limiting or demultiplying for over temp.of

IPM module

D17

Meaning

D18

Meaning

blink 1 time

too low DC input voltage

On

receiving or sending indoor data

blink 2 times

too high DC voltage

when no short-circuit in

computer monitor port

off

receiving or sending indoor data finished

blink 3 times

AC current protection

blink

normal communication between main borad and

driving board

blink 4 times

IPM abnormality

short-circuit in

computer monitor port

not

blink

abnormal communication between main board and

driving board

blink 5 times

reserved built-in PFC

protection

blink 6 times

start-up failure

blink 7 times

phase-losing or out of

control

blink 8 times

first PFC protection ;then

module protection

-14-