When unit is
cooling or
heating, both
compressor and
outdoor fan don't
run

When unit is
cooling or
heating, the
compressor runs
but outdoor fan
doesn't run

When cooling or
heating, outdoor
fan runs, but
compressor
doesn't run.

When cooling or
heating, outdoor
fan runs, but
compressor
doesn't run.

Fan doesn't run

when FAN mode

is set

Abnormal power supply of outdoor unit

Damage of outdoor main control board

Breakage of outdoor power module

Improper setting of temperature

Breakage of outdoor fan motor

Wrong wire connection

Breakage of outdoor main control board

Breakage of outdoor fan capacitor

Malfunction of compressor

Poor contact of connection between the
main control board and module

Abnormal input of power module

Abnormal output of power module

Compressor temperature is too high

Wrong wiring

Damage of outdoor main control board

Check the circuit according to circuit diagram

Replace the main control board

Replace the power module

Adjust the set temperature

Replace the fan motor

Wire according to the circuit diagram

Replace the main control board

Replace the fan capacitor

Replace the compressor

Re-fasten the connection

Check if input is 320V. If not, replace the
rectifier

Replace the power module

Cool the compressor for 30 min before running

Wire according to the circuit diagram

Replace the outdoor main control board

Burn-out or broken wire of indoor fan
motor

Wrong wiring

Circuit break or damage of fan motor
capacitor

Repair or change the fan motor

Wire according to the circuit diagram

Replace the indoor main control board