Seiko Instruments LTP F Series User Manual

Page 31

Advertising
background image

3-13

A sample motor current control is shown in Figure 3-8.

275

275mA)

0

10

4

10

Figure 3-8 Sample of Motor Current Control

Drive the motor at Im (approx. 275 mA) during the start-up step and the stop step. Do not switch the
current.

Continuous driving

When the motor is driven for a long time or motor drive is often performed repeatedly, the motor heats
up and may not be able to show necessary performance. To avoid it, when the motor was driven, set
up the pause time of the same period of time as that the motor was driven. Furthermore, make one-
time continuous driving 6 minutes (max.).

Motor drive

current

More than

2.5ms

Less

than

2.5ms

More than

2.5ms

More than

2.5ms

More than

2.5ms

Approx.

Advertising