5 printed position of the data (ltpf347) – Seiko Instruments LTP F Series User Manual

Page 37

Advertising
background image

3-19

Table 3-8 DST Blocks and Activated Heat Elements (LTPF347)

DST Number

Heat Element Number

Dots/DST

DST1

1 to 384

384

DST2

385 to 640

256

3.5.5 Printed Position of the Data (LTPF347)

384 data dots from No.1 to No.384 which are transferred through DAT IN1 terminal and 256 data dots
from No.385 to No.640 are printed as shown in Figure 3-12.
For No.1 to No.32 of 384 data dots transferred from the DATA IN1 and No.609 to No.640 of 256 data
dots transferred from the DATA IN2, set the NULL data.

Figure 3-12 Printed Position of the Data (LTPF347)

LTPF347 printer mechanism

1 2 3 4 5 6 .................... 638 639 640

Paper feed direction

Print surface

Data print sequence

Paper

DATA IN1 Data input sequence 1 2 . . . . . . 383 384

Data in

DATA IN2 Data input sequence 385 386 . . . . . . 639 640