H1000 pilot, Description/installation, Clutch voltage selection – B&G H1000 Autopilot User Manual

Page 34

Advertising
background image

h1000 pilot

description/installation

Page 33

clutch voltage selection

The h1000 pilot computer unit can output different clutch/solenoid voltages depending upon the size of
rudder drive unit fitted. The clutch/solenoid valve is only required for rams or rotary drive units. This is
achieved by setting dip-switches on the computer drive PCB. Access to the switches is obtained by
removing the four screws holding the computer PCB into the lid of the computer unit and then carefully
lifting the PCB clear.

Set the switches as per the table below. The default setting is 9V, switch 4 ON, which is suitable for Size
0, 1, and 2 12V rams.

Dip Switch

Clutch Voltage

Drive Size / Type

1 24V 24V

Rotary

2

18V

Size 2 and 3, 24V Rams

3 12V 12V

Rotary

4

9V

Size 0, 1 or 2 12V Rams