h1000 pilot

description/installation

Page 43

non-B&G paddle connection

Any non-B&G speed sensor used with this system must have a speed signal output from a hall-effect
device giving positive pulses of 12V maximum.

1.

Locate the cable from the speed sensor to the instrument input.

2.

Cut cable (if necessary) and insert a junction box (B&G part no. 288-00-001). Connect like colour
to like colour.

3.

Use a length of 2-core screened cable (B&G part no. 135-0B-098 9m/30ft) to connect the speed
signal and ground of the paddle sensor to the speed input of the ACP computer unit.

4.

Calibrate the speed input in accordance with the instructions given in the Speed Calibration
section of the h1000 System User manual.

ACP Boat Speed

Terminals

Function

Cable

135-0B-098

Green

Speed signal input

Red wire

Red Not

used

Not

used

Black Ground

Blue

wire

Silver Screen Screen

Non B&G
Paddle Unit

Non B&G Display