calibration

h1000 pilot

Page 52

speed calibration

adjustment – ref

Reference speed adjustment, allows for quick and easy calibration of your boat speed readings against a
known calibrated source; for example, speed over the ground from a GPS or alongside another boat with
a calibrated log.

1) From

the

Speed Calibration Menu, highlight

Adjustment

, select

ref

from the drop-down box and

press ENTER to select. The display will now show the Reference Speed page.

2) If speed over the ground data is available on the system from a GPS, the h1000 will

automatically detect this and display this value on the screen with the message from SOG. To
accept this value, simply highlight

OK

and press the ENTER key.

3)

If speed over the ground is not available, simply highlight the speed value and, using the
UP/DOWN and ENTER keys, adjust the value to the known reference boat speed.

4) Next,

highlight

OK

and press ENTER to complete the operation.

sea temperature units

Sea temperature information can be shown in

qc or qf. To change the units, highlight Sea temp and

press ENTER. Using the UP/DOWN keys, highlight the desired choice, and press the ENTER key to
memorise.