15] read the special i/o parameters, 16] set the special i/o parameters, 15] read the special i/o parameters -11 – Sharp JW-21MN User Manual

Page 50: 16] set the special i/o parameters -11

Advertising
background image

10-11

[15] Read the special I/O parameters

Read out parameter data of special I/O modules (other than JW-21MN) from the control module.
[Write mode assignment]: None
[Communication format]

Command

Response

[Ex.] To read parameter address data 030 to 032

(8)

of the special I/O module (Module No. 3). (Except

one with

(8)

, the data in cells are in hexadecimal notation)

Command

Response

[16] Set the special I/O parameters

Write parameter data of the special I/O module (other than JW-21MN) to the control module.
[Write mode assignment]
2 (and when the PC stops operation by "PC operation stop F8

(H)

" command).

[Communication format]

Command

Response

[Ex.] Write 14

(H)

, 00

(H)

, and 33

(H)

to parameter address 040 to 042

(8)

of the special I/O module (module

No. 2).(Except ones with

(8)

marks, the data in cells are in hexadecimal notation)

Command

Response

"+"

"C"

"L"

"A"

CMD SUB

ATTR UNO PAADR

N

"+"

ACK

"C"

"L"

"A"

CMD

SUB ATTR UNO PAADR

N

D1

DN

2B

43

4C

41

42

03

00

03

030

(8)

003

(8)

"+"

"C"

"L"

"A"

CMD

SUB ATTR UNO PAADR N

2B

00

43

4C

41

42

03

00

03

030

(3)

003

(3)

15

21

03

ACK

CMD

SUB

030

031

032

Read out data

"+"

"C"

"L"

"A"

CMD SUB

ATTR UNO PAADR

N

D1

DN

"+"

ACK

"C"

"L"

"A"

CMD

SUB ATTR UNO PAADR

N

2B

43

4C

41

42

13

00

02

040

(8)

003

(8)

14

00

33

"+"

"C"

"L"

"A"

CMD SUB ATTR UNO PAADR N

040

041

042

Write data

2B

00

43

4C

41

42

13

00

02

040

(8)

003

(8)

ACK

CMD

SUB

(Symbols other
than the left:
See page 10-3.)

Symbol

Data

Details

CMD

42

(H)

Function code

SUB

03

(H)

Sub code

UNO

00 to 07

(H)

When connected to a JW20/JW20H, set the value for
the module No. switch

00 to 37

(H)

When connected to a JW30H, the upper digits are rack

No. and the lower digits are the value for module No.

switch.

PAADR

000 to 177

(8)

Read out start address

N

01 to 80

(H)

Number of bytes to read out

D1 to DN

See the example Read out data (for number of bytes of reading data)

(Symbols other
than the left: See
page 10-3.)

Symbol

Data

Details

CMD

42

(H)

Function code

SUB

02

(H)

Sub code

UNO

00 to 07

(H)

When connecting to JW20/JW20H, set value of module

No. switch

00 to 37

(H)

When connecting to JW30H, upper digits are rack No.
and lower digits are set value for module No. switch.

PAADR

000 to 177

(8)

Write start address

N

01 to 80

(H)

Number of bytes to write

D1 to DN

See the example Write data (for number of bytes of writing data)

Advertising