E

In order for the scale pointer to be accurate, it must be

calibrated.

We recommend calibrating your scale pointer any time you

adjust the drum height or table lift screws.

To.calibrate.the.scale.pointer,.do.these.steps:

1. Sand a workpiece (see Figure. 41). with the drum

sander and measure the thickness of the sanded

workpiece.

2. Loosen the screw that secures the scale pointer and

adjust it to the thickness of the workpiece.

Scale.Pointer.Calibration

5. Lower the table three full turns of the handcrank.

6. Turn the adjustment bolt (Figure.39).as required so

the roller just touches the gauge board (see

Figure.

40).

.

Note: To gain better access for the following adjust-

ments, you can open the side covers.

7. Repeat

Step.6 for the opposite side of the same

pressure roller.

8. Repeat

Steps.6–7 with the second pressure roller.

Each pressure roller should look like

Figure.40 when

properly adjusted.

9. Tighten the jam nuts on the adjustment bolts (see

Figure.39) to lock the adjustment.

Figure.39. Gauge boards below rollers.

Adjustment

Bolt

Gap

Just Touching

Figure.40. Gauge boards touching rollers.

Figure.41. Pointer calibration.

Pointer

Screw