Setting the Time Data

Chapter 3 Convenient Functions for Editing Operation

34

Chapter 3

Convenient Functions for Editing Operation

7

Press the SET (YES) button.

The message “NOW SAVING...” appears on the
monitor screen, “Saving...” appears in the time
counter display, and the new settings are stored in
the unit’s memory.
After this saving operation is completed, the
monitor screen and the time counter display return
to their usual status.

Note

The set data may be lost if you power off the unit
while the above saving operation is in progress.
Wait until the saving operation is completed before
powering off.

Advancement of internal time code
generator

The internal time code generator can advance in either
of two modes, which can be set via “RUN MODE”
under the TIME CODE menu item.

FREE RUN: Advancement starts when the data

saving operation is completed.

REC RUN: Advancement starts when recording

starts and stops when recording stops.

To set the current time as the time code’s
initial value

In Step

2

above, set “RUN MODE” under the TIME

CODE menu item to “FREE RUN”, then set the
current time (format: HH:MM:SS:FF = hours:
minutes:seconds:frame number) in Step

3

and

subsequent steps.

Synchronizing Internal and
External Time Codes

When the unit is equipped with an optional DSBK-
130/130P Time Code Input/Output Board, the internal
time code generator can be locked to (synchronized
with) an external time code (LTC) that is input to the
unit.

To synchronize the internal time code to
external time code

Input an external time code (LTC) signal to the unit’s
TIME CODE IN connector, then set “TC MODE”
under the TIME CODE menu item to “EXT REGEN”.
The internal time code generator locks onto the
external time code and starts advancing. Once the
internal time code generator has become synchronized
in this way, you can disconnect the external time code
input and this unit will maintain the synchronized time
code.

Note

When the selected input mode is “QSDI” (the QSDI
indicator is lit in the INPUT MODE display), setting
“TC MODE” under the TIME CODE menu item to
“EXT REGEN” causes the internal time code
generator to automatically synchronize with the
external time code input to the unit via the QSDI
interface.

Once an external time code signal has been input, the
unit’s internal time code advancement mode and frame
count mode are automatically set as shown below.

Advancement mode: FREE RUN
Frame count mode: Same as external time code

(drop frame or non-drop frame)

To confirm external synchronization

Press the STOP button to put the unit into stop mode,
then press the REC button.
Look at the time counter display and check that the
time code value displayed there matches the external
time code value.