Sony 5500 User Manual

Page 155

Advertising
background image

155

Menu List

App

end

ix

605

TAPE TIMER
DISPLAY

+/– 12H
[24H]

Selects whether the CTL counter operates in 12-hour
display mode or 24-hour display mode.
+/–12H: 12-hour display mode
24H: 24-hour display mode

Note

In the ±12-hour display, the tens digit of the hours value is
dropped.

606

TCG MODE select

[preset]
regene
auto

Selects the time code to which the internal time code
generator synchronizes.
preset: By an operation on the front panel or by remote

control from a device connected to the REMOTE 1-
IN(9P) connector, the initial value of the time code
generated by the internal time code generator can be
preset.

regene: The internal time code generator is synchronized

(“regene”) to the time code values read by the internal
time code generator.

auto: Operates in regene mode when either assemble or

insert mode is selected and operates in preset mode
when any other mode is selected.

607

TCG REGENE
SOURCE select

SDI-LTC
SDI-VITC
ext-LTC
int-VITC
[int-LTC]

If item 606 is set to “regene”, this selects the source of the
synchronization of the time code generated internally.
int-LTC: When the time code played back from the time

code track on the tape is used.

int-VITC: When the time code played back from the “AUX

data” in the video signal on the tape is used.

ext-LTC: When the external time code input to the TIME

CODE IN connector is used.

SDI-VITC: When the VITC input to the HD SDI INPUT

connector is used.

SDI-LTC: When the LTC input to the HD SDI INPUT

connector is used.

608

TCG/UBG REGENE
MODE

TC
UB

Selects the regenerate signal when the time code
generator is in regenerate mode (when item 606 is set to
“regene”) or during auto edit mode.
TC & UB: The time code signal and user bits signal are

both regenerated.

TC: The time code signal is regenerated.
UB: The user bits signal is regenerated.

609

REC RUN/FREE
RUN select

[free run]
rec run

This selects the way in which the time code advances.
free run: Regardless of the operation mode of this unit, the

time code advances all the time that the power is on.

rec run: The time code advances only during recording.

Note

When using this setting, set item 606 to “preset”.

610

DOWNCONVERTER
VICT output

[on]
off

Selects whether or not to insert VITC data in the HD-SD
converter output.
on: VITC data is inserted.
off: VITC data is not inserted.

611

VITC POSITION-1
select (NTSC)

12,281 line

[16,279 line]

20,283 line

When 29.97PsF/59.94i mode is selected on the VTR, this
setting specifies the lines in which the VITC signal is
inserted.
It can be inserted in any lines from 12,281 to 20,283.

Note

Items 611 and 612 allow VITC to be inserted in two lines.

Item number

Item

Setting

Function

[TC UB]

&