3-5 selecting the drop frame mode (df/ndf), 3-7 selecting ctl display mode (tape timer), Area (tc2 sel) – Sony 5500 User Manual

Page 61: When hksr-5001 is installed)

Advertising
background image

61

4-3 TC Menu

C

h

ap
te

r 4

M

enu

Se
tt

in

g

s

4-3-5 Selecting the Drop Frame
Mode (DF/NDF)

Press the [F9] (DF/NDF) button to select the running mode
for the CTL counter and the time code generator.
DF: Drop frame mode

1)

(DF is displayed.)

NDF: Non-drop frame mode

2)

(NDF is displayed.)

auto: The unit switches to drop frame mode when the field

frequency is 29.97 Hz, and switches to non-drop
frame mode when the field frequency is 30 Hz.

1) Drop frame mode

In order to compensate for differences between time code values from the
time code generator and the actual time that occurs when the frame
frequency of this unit is 29.97 Hz, the drop frame mode causes the time
code generator to omit the first two frames (frame 00 and 01) in each
minute except the tenth.

2) Non-drop frame mode

In this mode, drop frame mode processing is not performed. Since there is
no frame cutting, a discrepancy of about 86 seconds occurs each day in the
case of a frame frequency of 29.97 Hz.

• This setting is only active when the frame frequency of

the unit is 29.97 Hz or 30 Hz.

• When the [F7] (TCG MODE) button is set to “regene”,

the drop frame mode is inoperative since the time code
generator is synchronized to the playback time code.

4-3-6 Selecting the Content of the
Second Time Code Display Area
(TC2 SEL)

Select the content of the second time code display area
using the [F10] (TC2 SEL) button.

When the two-unit editing display, a warning, or similar is
shown, the second time code display area does not appear.

For details about the warnings, see “Warning Messages”
on page 135.

4-3-7 Selecting CTL Display Mode
(TAPE TIMER)

Press the ALT/[F1] (TAPE TIMER) buttons to select a 12-
hour or 24-hour clock for the CTL display.
+ –12H: 12-hour clock
24H: 24-hour clock

4-3-8 Presetting Pulldown Time
Code (PDPSET MENU)
(when HKSR-5001 is installed)

To preset the pulldown time code when this VTR is
operated in 23.98PsF/24PsF mode, use the following
procedure.

1

Press the TC button, then press the ALT button.

You can also press the ALT and TC buttons
simultaneously.

2

Press the [F2] (PDPSET MENU) button.

The PDPSET menu appears.

3

Press the [F1] (PRESET MODE) button to select 24F
or 30F time code to be preset.

Notes

Setting

Time data displayed

OFF

No display

LTC

LTC value read from the time code reader

Auto

When the playback speed is within the range ±1/2
normal speed, then VITC, and if outside this
range then the LTC is displayed.

VITC

VITC value read from the time code reader

CTL

CTL signal count value

UBR

User bits read by the time code reader (LTC)

UBV

User bit value read from the time code reader
(VITC)

TCG

Value generated by the time code generator

UBG

User bits value generated by the time code
generator

2

5

4

3

1

P R E S E T

M O D E

2 4 F

D F

F 2

P D T I M E

S E T

E X I T

P D T C

D F / N D F

N D F

I N T R P

D F

2 F O

00

H

00

M

00

S

00

F

00

H

00

M

00

S

00

F

2 4 F

3 0 F

I N T R P

Advertising