Other items (nos. t01 to ...) – Sony 5500 User Manual
Page 178
178
Menu List
App
endi
x
Other Items (Nos. T01 to ...)
Items T01, T02, and T04 are reset to their factory default
settings whenever the power is turned off.
A10
TC sense data
select
[LINE/24F]
FC/30F
Specifies whether or not the time code information of FC
output signal is returned when time code sense command
is input through the 9-pin connector.
LINE/24F: Time code information of main output signal is
returned. In pulldown conversion mode, 24-frame/sec
time code information is returned.
FC/30F: Time code information of FC output signal is
returned. In pulldown conversion mode, 30-frame/sec
time code is returned.
Notes
• Pulldown output signal and 30-frame/sec time code are
synchronized only when this unit is set to PLAY LOCK
mode. To synchronize the signals, set item A05 “PD EXT
SD REF LOCK MODE” to “lock2”.
• When editing pulldown output signals with a VTR
operating in 30F mode, it may not be possible to achieve
sync within 5 seconds. If this occurs, set the preroll time
to 7 seconds.
Also, normal operation is not possible with devices
engaged in player sync.
Item number
Item
Setting
Function
T01
AUTO REPEAT
MODE
[off]
on
Selects the repeating operation of PREVIEW in automatic
editing.
off: PREVIEW in automatic editing is not repeated.
on: PREVIEW in automatic editing is repeated. To stop,
press the STOP button.
T02
INTERNAL VIDEO
SIGNAL
GENERATOR (HD)
[off]
COLOR BARS
MULTI BURST 1
MULTI BURST 2
10 STEPS
PULSE & BAR
RAMP
BLACK
Selects the test signal output by the signal generator built
into the VTR.
off: The test signal is not generated, and the VTR operates
normally.
all other settings: The test signal is output from the VTR. At
this time it is also possible to record the signal.
T04
INTERNAL AUDIO
SIGNAL
GENERATOR
[off]
silence
1 kHz sine
Selects the operation of audio test signal output.
off: The audio test signal is not output.
silence: Mute signal.
1 kHz sine: 1 kHz (In this case, a 1 kHz -20 dB FS sine
wave is supplied to all audio inputs.)
Notes
• When “silence” or “1 kHz sine” is selected, the AUDIO IN
and AUDIO MONITOR L/R buttons light up.
• When the unit is operated in the 23.98 PsF or 24 PsF
mode with “1 kHz sine” selected, the output signal is
960 Hz.
Item number
Item
Setting
Function
Note