6. System Configuration and Management

6.1.

6.1.

6.1.

6.1. Equipment Power-on

When the 3P@C 4450E is installed, you may power it on. The following phenomena will occur when the
equipment is powered on:

„

First the RUN indicator of the SMUB will be on, and the RUN indicator of the ADUB/ADUC or
the VDUB will start to flash.

„

After that, the 3P@C 4450E switch will conduct self-check and begin to load system software.
At this time, the “LINK” indicator of a port that has been connected reliably will be solid on
while the ACTIVE indicator will be off. About 90 seconds later, the switch enters the normal
working state. For the connected port, if the ACTIVE indicator starts flashing, it indicates that
this port is transmitting or receiving data.

„

If the Console interface is now connected to a PC with a HyperTerminal, then such product
information as company name, product serial number and hardware and software versions will
be displayed on the PC screen, and operation prompt will be given when the self-check is
completed. After you correctly log in the system, you may enter the command line
management system to perform 3P@C 4450E configuration and management. For the
specific configuration method, please refer to the

3P@C 4450E IP-DSLAM Software

Configuration Manual

. If the Console interface is not connected to the PC, please refer to the

Console interface connection described in Chapter 4.

6.2.

6.2.

6.2.

6.2. Setting Up the Configuration Environment

6.2.1.

6.2.1.

6.2.1.

6.2.1. Local Configuration via the Console Interface

When the 3P@C 4450E is powered on, the system will first complete the self test. If everything is normal, the
3P@COS login interface will appear. The specific procedure is shown as follows:

Step 1

Connect the Console interface on the SMUB to a certain terminal
according to the method described in Chapter 4, and conduct the
corresponding setting.

Step 2

When the 3P@C 4450E is powered on, such information as company
name, production date and product version and some self test
information of the system are displayed on the terminal screen first, as
shown in the following:
3P@C 4450EV2 Boot Loader Version 2.03
Compiled: May 23 2003 14:46:07
SDRAM test....passed.

Base ethernet MAC address: 00:05:3b:00:04:99

Uncompress start...