Vdsl line maintenance, Sagem 3p@c – Sagem 4450E User Manual

Page 179

Advertising
background image

SAGEM 3P@C

3P@C Installation Manual

Page 12-22

Reproduction and communication in any form prohibited without the written permission of

SAGEM SA

Table 12-12 VDSL setting parameters and connection parameter record table

Set the restraint parameters

r1.04

Upstream [ ]
Downstream [ ]

on

[ ]

r2.08

Upstream [ ]
Downstream [ ]

Auto-
adaptation
mode

off

[ ]

r4.17

Upstream [ ]
Downstream [ ]

10M

[ ]

r8.33

Upstream [ ]
Downstream [ ]

Ethernet rate

100M

[ ]

r10.04

Upstream [ ]
Downstream [ ]

full

[ ]

r12.5

Upstream [ ]
Downstream [ ]

Duplex
mode.

half

[ ]

r16.67

Upstream [ ]
Downstream [ ]

on

[ ]

VDSL
Upstream/d
ownstream
rate levels

rom

Upstream [ ]
Downstream [ ]

Modem flow
control

off

[ ]

Others:

Actual connection parameters

on

[ ]

Upstream
rate

Auto-
adaptation

off

[ ]

10M

[ ]

VDSL
Upstream/d
ownstream
rate

Downstrea
m rate

Ethernet rate

100M

[ ]

full

[ ]

on

[ ]

Duplex
mode

half

[ ]

Modem flow
control

off

[ ]

Others

12.2.3. VDSL Line Maintenance

VDSL Service Common Faults and Handling

1) Unable to make calls and access the Internet

„

Confirm the correct and reliable connection of the splitter, VDSL Modem, subscriber terminal
PC and telephone.

„

Report the line faults to the 112 test terminal, and check the Internet accessing after
confirming the telephone service is normal.

2) Able to make calls but cannot access the Internet

(1) Confirm the power supply for the VDSL central office terminal is normal.

The data service is interrupted upon power-off, but the PSTN voice service cannot be affected because the in-
built splitter uses the passive working mode.

(2) Check whether the VDSL Link indicators of the ports related to the Modem or VDSL central office terminals is
in normal status, and if it is normal, you need to confirm it:

„

The connection between the splitter and the VDSL Modem is reliable and correct.

Advertising