Turbo function

The turbo function is available in Cool and Heat modes.

Dry function

Dry function is available in Cool and Dehumidifying modes.

Auto fan speed control

In this mode, indoor fan can run with Hig, Mid, Low speeds.

Up and down swing control

Displayer

Running figure and mode figure display

After powered on, the figure will be displayed, then only Power/running indicator turn on. When using

remote conroller to open the unit, it will turn on, at the same time to display current setting running modes.

Dual 8 display

PG motor lock protection

When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order

to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on,

that dual 8 will display lock error code H6; If current is unit off, will not display the block error information.

After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet

vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop

at current position, inner fan motor is running, guide louver will resume to swing.From Cool, Dry, Fan modes

to Heat mode, the guide louver will be opened at D position, when turn on swing will run at (A-D); from Heat

mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-C).

When unit is turned off, the guide louver will turn to position 0, the swing is only available after preset the

swing function, and indoor unit is running.

Note: When to set up at position L to B, A to C, B to D, the guide louver will swing between position W to D.

Tpreset

Tpreset

Tpreset

1hr.

2hrs.

2hrs. above

Tpreset temp.

Power-off Memory

Memory contents: Mode, UP/DOWN Swing, light, Set temp, Set fan speed.

After de-energized, and re-energized, the unit will start to run with the memory function automatically. The system, if the last

remote control signal do not set timer function, will memorize the last remote control signal and run according to it. If the last

remote control signal has set timer function, the system is de-energized before the set time,when re-energized, the system

will memorize the timer function, the set time will recalculate. If the last remote control signal has set timer function and the

system is de-energized after the set time, when re-energized, the system will memorize the running status before de-energized.

When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 16-30 ).
When the preset temperature display signal has been received, the nixie tube will display the preset temperature;
If the display ambient temperature signal has been received, the nixie tube will display the current indoor ambient
temperature, if to set up others by remote controller that the display will maintain its status. At displaying ambient
temperature, the unit received the remote control signal, it will display 5s preset temperature then turn to ambient
temperature display. The ambient temperature sensor malfunction will display F1; Indoor tube sensor will display
F2, wire jumper cap protection displays C5.