Sinclair KING ASH-09AK User Manual

Page 35

Advertising
background image

Improper set of temperature

Adjust set temperature

If cooling (heating) load is
proper

Check the forecasted load of cooling (heating)

The refrigerant has leakage or is
insufficient

heck and fill the leakage, then

vacuumize it and supplement the re-
frigerant as required

Leakage between the high pres-
sure and the low pressure in-
side the compressor

Replace the compressor

Malfunction of four-way valve

Replace the four-way valve

Local block of capillary

Replace the capillary

Blockage of cooling system

Judge whether the system is blocked by
observing the condensation of evapora-
tor and the pressure value of the high
pressure manometer and take measures
to deal with the system.

Malfunction of
r e f r i g e r a n t
flow

Heat insulation for the connection
pipes of the indoor unit and the out-
door unit is bad.

Make sure that heat insulation for the thick and thin pipes
is good. Heat insulation must also be provided for the
joint andthe exposed part of the copper pipe .

Block of outdoor heat ex-
changer

Clean the dust accumulated on the surface of
the heat exchanger.

Air filter were blocked

Clean the filter

Fan speed was set too slow

To set the fan speed to high or
middle speed

Air circulation

is insufficient

Fan rotation speed becomes
low

Capacitor
damage

Motor damage

Replace the capaci-
tor

Replace the motor

The installation position of the
outdoor unit is not appropriate.

Good ventilation must be provided for the
installation position of the outdoor unit.

The outdoor temperature is too high.

Properly install the rainproof plate or the sunproof plate. If the
maximum cool air still can not meet the requirement, it is sug-
gested to replace the air conditioner.

Keep certain air tightness indoors, try not to use
electricalappliance with large quantity of heat

The air tightness is not enough. People
come in and out too frequently. There
are heating devices indoors.

Poor COOL(HEA

T) operation

Advertising