Operating Procedures / Photos

Respectively unsolder the weld spots of main
capillary and auxiliary capillary to take off the
capillary.

10. Disassemble Capillary

11. Disassemble Gas and Liquid Valves

Unscrew the two bolts fixing gas valve and liquid
valve.Unsolder weld spots between gas valve and
and air-return pipe to remove the gas valve.
Unscrew the two bolts fixing liquid valve. Unsolder
weld spots between liquid valve and capillary to
remove the liquid valve.
(Note:During unsoldering ,wrap the valves with
wet cloth to avoid damage for high temperature.)

Bolts

12. Disassemble Compressor

Unscrew the three foot-nuts at the foot of the
compressor. Unsolder the suction and the dis-
charge pipes of the compressor,and then care-
fully remove the pipes to take out the compressor.

Liquid Valve

Gas Valve

Weld spots

Nuts with washers

Capillary