StarTech.com SV1115IPEXT User Manual

Page 58

Advertising
background image

54

log. Note that existing data is overwritten automatically when the 200
character limit is reached.
IPMI: Shows the IPMI command interface for the device, if applicable.
You can make as many changes as needed on this menu at one time,
before applying your changes. Once you are satisfied with the changes
you have made, click Commit changes to apply the new settings. Click
Refresh at any time to see an updated list of attached R-Port modules.

Advanced Configuration Using the Integrated SSH Shell

In most cases, configuring the SV1115IPEXT to the same settings
as the R-Port devices you are connecting should allow the devices
to work with a minimum amount of configuration. However, you can
also change the default settings on each R-Port device to fit your
preferences and the needs of your application.
If you click the Connect… button next to the device you want to
configure, two new windows will appear. The smaller of the two is
a login screen; the other is a SSH terminal window. Click the login
window and sign in as admin (using the same password as the Web
interface) to activate the terminal window. You will see a welcome
banner similar to the following:

Baud rate: 115200 bps, 8N1

Connected to #1: (none)... (Press Ctrl-Shift-_ for menu)

You are now connected to the R-Port module in a live terminal session.
Commands you type will be echoed on the terminal screen. The
module also offers a simple menu system that allows you to change its
configuration settings (similar to the function of the menus in a terminal
software package). Press [Ctrl] - [Shift] – [_] (underscore) on the
keyboard to access the menu. It will be similar to the following:
RS-232 Menu (#1: (none), 115200 bps, 8N1)
Q – Disconnect
# - Send break
H – Hangup line (drop DCD)
E – Send Ctrl-Shift-_

Advertising