Installation

5

For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

Primary Pump Discharge
Pipe (cut to fit)

Primary Sump Pump
Discharge Port

Primary Sump Pump
Check Valve

Flow Arrow; Must point
AWAY from Pump being
Protected

1-1/2"x1-1/4" Slip Reducer
Bushing*

#

1-1/2"x1-1/2" Slip Coupling*

Not to scale;
wiring omitted
for clarity.

1-1/2"x 1-1/2" slip x
1-1/4" FNPT Tee*

1-1/4”x1-1/4”
Check Valve
Assembly*

Teflon tape all
threaded joints

Battery Back Up
Sump Pump*

Auxiliary Check Valve*
(

See Important Check Valve

Warranty Note, Below)

Alternate Installation
for a Shallow Sump

“Easy Install” Layout

5763 0108

1-1/4”x1-1/4”
Close Nipple*

Switch with Clamp*

##

Notes:

#

* Supplied with the Battery Backup System.
Use if necessary to adapt a 1-1/4” discharge pipe to the 1-1/2” fittings supplied.
Use to adapt the auxiliary check valve to the discharge pipe.
Water level when the switch shuts off must be above the BBU pump intake.

##

Discharge pipe
cutoff piece

Upper Discharge pipe

Hose Coupling with Clamps*

1-1/2"x1-1/4" Slip
Reducer bushing*

Check Valve Flapper(s) must swing in direction shown.
Flow arrow(s) must point AWAY from pump being protected.

The 1-1/4” X 1-1/4” Check Valve Assembly must be installed
as shown or the warranty is void. Do not use a wrench (see
Installation Step 4, Page 4)! If the Primary Sump Pump
does not have a check valve installed as shown below the
Tee, the Auxiliary Check Valve must be installed as shown
or the warranty is void.

IMPORTANT CHECK VALVE/WARRANTY NOTE:

Figure 2: Typical Installation Layouts