For parts or assistance, call Simer Customer Service at

1-800-468-7867 / 1-800-546-7867

Installation

9

LED Operating Code Display

System Operating Condition

Charging

Battery status

Pump status

AC power

Silenced audible alarm

System Alert

Indicates 115V AC Power is connected

NOTE: All of the situations listed above indicate normal system operation; no action is required.
However, if the BBU pump is running or has run, check the primary pump and actively monitor the
charger status for battery life. Always reset the charger after the pump runs.
During normal system operation, the ‘System Alert’ LED does not light up. The “AC Power” LED
is lighted as long as the system is plugged in to an operating AC power circuit.

Indicates Pump is running (continuous LED)

Indicates Audible alarm is switched off

Indicates Battery is charging normally

Indicates Continuous LED: battery charge is above 20%,

system is maintaining charge

Indicates Slow flashing LED: battery charge is below 20%

LED is Flashing (Slow)

=

LED is OFF

LED is ON Continuously

=

=

LED is Flashing (Fast)

=

Indicates Fast flashing LED: Pump has run

Indicates Fast flashing LED: Battery pre-qualification test is running

TABLE II – Operating Code Displays (LEDs Lighted Continuously or Flashing)

Control LED:

Continuous Illumination Indicates Normal Operation:

AC Power

AC power is present.

Pump Status

The float switch has been activated. The LED remains on (flashing) after the pump
has stopped. Depress the‘System Test’ button to reset it.

Silenced Audible Alarm

Audible Alarm has been silenced. Press and release the ‘Silence Alarm’ button to
reset (activate) the audible alarm and turn OFF the LED.

Charging

Indicates that the battery is charging – see Table II, above.

Battery Status

A. Continuous ‘ON” - the battery voltage is above 10.9 Volts DC and capacity is

above 20%.

B. Slow Beep/Slow LED Flash - the battery’s capacity is below 20%, and voltage

is between 8.2VDC and 10.9VDC.

C. Fast Beep/Fast LED Flash - the battery has been discharged to less than

8.2VDC.

System Alert

Flashing (in unison with the buzzer) indicates that the charger has entered ‘Failure
Mode’. Press the ‘System Test’ and ‘Silence Alarm’ buttons to reset it.
NOTE: If the source of the failure is not corrected, the charger will reenter ‘Failure
Mode’. See Table IV for error code information.

TABLE III – LED Function Displays (LEDs Lighted Continuously)