Tcm error messages, Tcm error messages -14, Table 6-3. tcm error messages – Symbol Technologies MC3000 User Manual

Page 108

Advertising
background image

MC3000 Integrator Guide

6-14

TCM Error Messages

TCM validates the cells in the partition table when the Execute button is clicked. Cells highlighted in red contain an error. Partition
loading is disabled until all errors are corrected.

Table 6-3. TCM Error Messages

Error

Description/Solution

Failed to build images: flash file system DLL not
loaded!

TCM could not load the DLL required to build images for the targeting flash file system. Reinstall TCM
or recover the DLL.

Failure finding directory xxx

Building process failed because directory xxx was not found.

Failure creating volume

Building process failed because a certain disk volume could not be created.

Failure adding system file to image

Build process failed because TCM failed to add a certain system file to the disk image.

INVALID PATH

The path for the image file to build is not valid.

Nothing Selected To Build

In the Config Build window, no item is selected to build.

Illegal ESS ID

In the Build ESSID Partition window, no ESS ID was entered or the ESS ID entered was illegal.

Disk Full

TCM failed to create hex image file at the selected path. Check available disk space.

Target Disk Full

Build process failed because TCM failed to add file to the image of a disk volume. Remove some files
or increase the disk size.

Hex file is READ ONLY

The hex image file to be created exists and is read only. Delete the existing file or change its attribute.

Error opening the file xxx with write access

TCM could not open file xxx with write access. Check if file is in use.

Failure creating binary file

TCM failed to open/create an intermediate binary file.

Hex File To load is missing or invalid

In Load Terminal window, the file selected to load has invalid status.

Could not locate mobile computer name in TCM.ini file While loading the Script Properties window, TCM could not find the TCM.ini section corresponding to

the mobile computer type specified by the current opening script. Either TCM.ini or the script file is
invalid.

Incorrect disk sizes in TCM.ini file

The total disk size specified in the script does not match the total disk size defined in the corresponding
TCM.ini section. Check if the script is corrupt or the TCM.ini has changed after the script was created.

INVALID DIRECTORY

In Script Properties window, the selected System File Path is not a valid directory.

One of the disk sizes is one sector in size

In Script Properties window, one of the disks is too small (one sector in size). This may cause problem
while building images, especially when cushion is enabled. Increase the disk size.

INVALID VOLUME NAME

In Script Properties window, one of the volume labels is not valid.

Corrupt TCM.INI file! (Invalid value of VolumeDivisor)

The VolumeDivisor entry is missing or invalid in the TCM.ini. Reinstall TCM or recover TCM.ini.

Invalid version of TCM script file

The TCM script was not created by this version of TCM.

Corrupt or missing TCM.ini file

TCM could not find TCM.ini file.

FAILED CONNECTION TO COM PORT (Could not get
status)

While downloading images to mobile computer, TCM failed to connect to the selected COM port. Check
if the COM port is free and is properly configured.

FAILED CONNECTION TO TERMINAL (Terminal Not
Connected Properly/Terminal Not Ready to Receive)

While downloading images, TCM failed to connect to the mobile computer. Check if the correct flow
control protocol is selected and the mobile computer is properly connected and is in a listening state.

Advertising