Table 10-1. Troubleshooting the Mobile Computer

Problem

Cause

Solution

Mobile computer does not turn
on.

Main battery not charged.

Charge or replace the main battery in the mobile computer.

Main battery not installed
properly.

Ensure the battery is installed properly

.

For more information see,

Install Main Battery on

page 1-7

.

System crash.

Perform a warm boot. If the mobile computer still does not turn on, perform a cold boot

.

For

more information see,

Resetting the Mobile Computer on page 1-14

.

Battery did not charge.

Battery failed.

Replace battery. If the mobile computer still does not operate, try a warm boot, then a cold
boot. For more information see,

Resetting the Mobile Computer on page 1-14

.

Mobile computer removed
from cradle while battery was
charging.

Insert mobile computer in cradle and begin charging. The Standard Battery requires up to four
hours to recharge fully and the Extended Life Battery requires up to six hours to recharge fully.

Extreme battery temperature. Battery does not charge if ambient temperature is below 32°F (0°C) or above 104°F (40°C).

Cannot see characters on screen. Mobile computer not powered

on.

Press the Power button.

During data communication, no
data was transmitted, or
transmitted data was
incomplete.

Mobile computer removed
from cradle or unplugged from
host computer during
communication.

Replace the mobile computer in the cradle, or reattach the cable and re-transmit.

Incorrect cable configuration.

See

Chapter 2, Accessories

for cable configurations.

Communication software was
incorrectly installed or
configured.

Perform communication setup as described in

Communication Setup on page 2-29

.

Mobile computer does not emit
sound.

Volume setting is low or
turned off.

Mobile computer may be a beeper only configuration or incorrect setting is programmed into
device.

Mobile computer turns itself off. Mobile computer is inactive.

The mobile computer turns off after a period of inactivity. This period can be set from one to
five minutes, in one-minute intervals.

Battery is depleted.

Recharge or replace the battery.

Battery is not inserted
properly.

Insert the battery properly. For more information see,

Install Main Battery on page 1-7

.

Tapping the window buttons or
icons does not activate the
corresponding feature.

Touch screen not calibrated
correctly.

Re-calibrate the screen.

From the mobile computer, Demo window double-tap the Ctl Panel icon and double-tap on
Touch Calibrate. Follow the screen prompts.

The system crashed.

Warm boot the system. To perform a warm boot, see

Resetting the Mobile Computer on page

1-14

.

A message appears stating that
the mobile computer memory is
full.

Too many files stored on the
mobile computer.

Delete unused memos and records. If necessary, save these records on the host computer.

Too many applications
installed on the mobile
computer.

Remove unused installed applications from the mobile computer to recover memory.