Okidata b6100 series, Okidata b8300 series – Summit BROTHER HL-630 OPC User Manual

Page 24

Advertising
background image

24

engine is the Okidata OL-400/800, but the first
actual reset procedure is for the OL-800 series only,
followed by other machines that use the same engine
but have different reset procedures. Just to make
things a little crazier, there are also machines that
use different engines, but use the same reset
procedure. These are grouped as above, but with a
note that says what other machines also use that
procedure.
Hopefully this will help clear up some of the
confusion on what procedures to use.



Okidata B4200/4300 Series

Okidata OPC Cartridge Part # 42102801

25,000

B4200:
Start the status monitor for the printer. Click on the
Printer Setup Tab-Printer Menu Button-Maintenance
1 Tab. Click the (RESET) button next to the drum
counter, then click on OK button to reset the drum
counter.

B4300:
Press the ONLINE button to return the printer to off
line status. Press the MENU button until
MAINTENANCE MENU is displayed, then press
the SELECT button. Press the ITEM button until
DRUM COUNT RESET is displayed. Press the
SELECT button and drum counter is reset.




Okidata B6100 Series

Okidata Cartridge Part # 52113704, 52113701

6,000, 15,000 respectively

Press the MENU button until the display shows
“paper menu”. Press NEXT 4x until the display
shows “System Menu”. Press SELECT 1x until the
display shows “Factory defaults”. Press NEXT 7x
until the display shows “Reset Toner Life”. Press

SELECT 1x until the display shows “Resetting
Toner page Count”. Press READY


Okidata B6200/6300 Series

Okidata Cartridge Part # 52114501, 52114502

(6300 only)

OEM Stated Yield: 10,000, 17,000 respectively

Unlike most of the other Okidata machines, these

cartridges use a chip that has to be replaced. It uses

an odd round style ship, and there are many

manufacturers using them. Most have different

chips. Make sure you have the correct chip for the

machine it is intended for.

Okidata B8300 Series

Okidata Cartridge Part # 56115001

OEM Stated Yield: 27,000

NOTE: I have not seen these cartridges or machines.
When a new cartridge (OEM) is installed, it should
clear the message. (You have to install it with the
power off). If the power is left on. It will not reset
itself, then the following complicated procedure
must be followed. At this point I do not know if the
cartridge has a reset gear or a chip.

Enter the PCU Diagnostic mode by turning the
printer off and holding down the MENU and OK
buttons on power up. (Release the buttons once you
are in the PCU DIAG MODE). Press the MENU
button 14x until the display shows “COUNTER
DISPLAY”. Press the MENU button and the
BACK?C button at the same time. This will put the
printer into the “Feed Counter Clear Mode”. Release
the buttons. Press the up arrow 5x until the display
shows “Toner Counter Clear”. Pres the OK button,
the display will show “Toner No”. Press the Up
Arrow 1x so the display shows “Toner Yes”, Press
the OK button. The Green data light will flash to
indicate the process is complete. Turn the printer off
and on to clear the PCU DIAG mode.

Advertising