Power status check CR0 or CR STATUS

00

Power on

80

Stand-by

40

Count down

20

Cooling

Lamp status check

CR LAMPSTS

00

Lamp On, only available for multiple lamps
model.

80, 40,20,10

Lamp off

Input source

CR SOURCE

ANALOG

Analog input

DIGITAL

Digital input

S-VIDEO

S-video input

VIDEO

Video input

Input status

CR SIGNAL

ON

Signal exists

OFF

No signal

Input Select

CR INPUT

1,2,3,4,5

Selected input mode

Temperature

CR TEMP

temperature

Actual temperature

Lamp use time

CR LAMPH

time

Lamp use time in hours

Projector use time

CR PROJH

time

Accumulated use time in hours

Network board ver-
sion

LR PJNETVERSION version number

Firmware version of network board

Model Name

CR MODELNM

model name

Model name, “PLC-XF60” etc.