11

in an alcove or closet, the entire floor must be covered by the panel.

Failure to heed this warning may result in a fire hazard.

Minimum clearances between the water heater and combustible

construction are 0 inch at the sides and rear, 5.5” (14.0 cm) from

the front and 18” (45.7 cm) from the top. (Standard clearance.) If

clearances stated on the heater differ from standard clearances, install

water heater according to clearances stated on the heater.

Adequate clearance 30” (76 cm) for servicing this appliance should be

considered before installation, such as changing the anodes, control

system components and gas valve.

A minimum clearance of 5.5” (14.0 cm) must be allowed for access to

replaceable and/or serviceable parts such as the thermostats, drain

valve, condensate drain, relief valve, clean out opening, and the vent

connection (exhaust elbow).

When installing the heater, consideration must be given to proper

location. Location selected should be as close to the wall as practicable

and as centralized with the water piping system as possible.

fIGure 2.

InsulatIon blanKets

Insulation blankets are available to the general public for external use on

gas water heaters but are not necessary with these products. The purpose

of an insulation blanket is to reduce the standby heat loss encountered

with storage tank heaters. Your water heater meets or exceeds the

Energy Policy Act standards with respect to insulation and standby loss

requirements, making an insulation blanket unnecessary.

Should you choose to apply an insulation blanket to this heater, you

should follow these instructions (For identification of components

mentioned below, see Figure 1). Failure to follow these instructions

can restrict the air flow required for proper combustion, potentially

resulting in fire, asphyxiation, serious personal injury or death.

• Do not apply insulation to the top of the water heater, as this will

interfere with safe operation of the blower assembly.

• Do not cover the outer door, thermostat or temperature & pressure

relief valve.

• Do not cover the instruction manual. Keep it on the side of the

water heater or nearby for future reference.

• Do obtain new warning and instruction labels from the manufacturer

for placement on the blanket directly over the existing labels.

coMbustIon aIr and ventIlatIon

A gas water heater cannot operate properly without the correct

amount of air for combustion. Do not install in a confined area such

as a closet, unless you provide air as shown in the “Facts to Consider

About Location” section. Never obstruct the flow of ventilation air.

If you have any doubts or questions at all, call your gas supplier.

Failure to provide the proper amount of combustion air can result

in a fire or explosion and cause death, serious bodily injury, or

property damage.

fIGure 3.

If this water heater will be used in beauty shops, barber shops,

cleaning establishments, or self-service laundries with dry cleaning

equipment, it is imperative that the water heater (s) be installed

direct vent so that all air for combustion and ventilation is taken

from outdoors.

Propellants of aerosol sprays and volatile compounds, (cleaners,

chlorine based chemicals, refrigerants, etc.) in addition to being

highly flammable in many cases, will also react to form corrosive

hydrochloric acid when exposed to the combustion products of

the water heater. The results can be hazardous, and also cause

product failure.

unconfIned space

An Unconfined Space is one whose volume IS NOT LESS THAN

50 cubic feet per 1,000 Btu/hr (4.8 cubic meters per kW) of the

total input rating of all appliances installed in the space. Rooms

communicating directly with the space, in which the appliances are

installed, through openings not furnished with doors, are considered

a part of the unconfined space.

Makeup air requirements for the operation of exhaust fans, kitchen

Advertising