Operating set point 120°f, Uim (user interface module), Control system operation – State Industries Premier Power Vent DV Series GP6 50 HTPDT 121 Series User Manual

Page 37

Advertising
background image

37

user Input buttons

• The up and down buttons are used to navigate menus and

adjust user settings.

• The operational buttons are used to enter/exit menus, select

menu items, activate adjustment modes and confirm or cancel

new user settings. The operational buttons are multifunctional,

their current function is defined by the text that appears directly

above each button on the LCD screen.

the desKtop screen

During normal operation the control system will display the

"Desktop" screen on the LCD which is the default screen. The

control system will return to the Desktop screen when there are

no active Fault or Alert conditions or when there has been no user

input for several minutes.

• Manufacturer and water heater model information is displayed

in Title Bar at the top of the Desktop screen. Menu titles are

displayed in the Title Bar when navigating the control system

menus.

• The first temperature shown on the Desktop screen, Tank

Temperature, is the temperature of the water inside the water

heater's storage tank - commercial models only.

• The Operating Set Point is also shown on the Desktop screen.

The Operating Set Point is the temperature at which the control

system will maintain the water inside the storage tank.

• Beneath the Operating Set Point is the "Status" line. The Status

line shows the current operational state of the control system in

real time. See Table 4 for a description of the various operating

states.

• The Desktop screen also displays animated "Status Icons" to

convey operational information, see Table 3 for a complete list

and description of the Status Icons.

overvIew

The water heaters covered in this manual are equipped with an

electronic control system that regulates water temperature inside

the storage tank. Heating cycles and ignition are managed by the

control system. The ECO (energy cut out), Flame Sensor, pressure

switches and Temperature Probe is monitored by the control

system. The Combustion Blower, Igniter and the 24 Volt Gas Valve

are all energized by the control system.

The main components of the control system are a UIM (user

interface module) and a CCB (central control board). The UIM

is located on the top front side of the water heater. The CCB is

mounted on top of the water heater inside a protective enclosure.

coMMercIal and resIdentIal Models

The water heaters covered by this manual are produced for

commercial and residential use. The control system is programmed

differently for commercial and residential models. There are two

differences in control system operation between the residential and

commercial products:

• Commercial models will display Tank Temperature on the

Desktop screen, residential models will not.

• Commercial models can regulate tank temperature up to a

maximum of 180°F (82°C), residential maximum is 160°F

(71°C).

control sYsteM navIGatIon

All operational information and user settings are displayed and

accessed from the UIM. The UIM houses the control system's LCD

(liquid crystal display) and five snap acting (momentary) user input

buttons; an up, down and three multifunction operational buttons

below the LCD, see Figure 35.

Operating Set Point

120°F

Status: Heating

MENU

HELP

GAS

OFF

O

N

MANUFACTURER / MODEL INFORMATION

LCD Screen

Information

Display

Status Icons

3 Operational buttons:

enter/exit menus,

select menu items,

activate adjustment modes,

confirm/cancel changes.

Up & Down buttons:

navigate menus,

adjust user settings

Title Bar

Operational buttons are multifunctional. Their current function is defined by

the text that appears directly above each button on the LCD screen.

UIM (user interface module)

Desktop Screen Shown

UP

DN

fIGure 35.

control sYsteM operatIon