Configuring the sensor i/o port, Sensor i/o setting page, Upper half of sensor i/o setting page – Sony SNC-VL10P User Manual

Page 27: Activity detection (ad), Output 1

Advertising
background image

Se
tt

in

g

s

b

y

A
d

m

ini

s

tra

to

r

Configuring the Sensor I/O Port — Sensor I/O Setting Page

27

Configuring the Sensor
I/O Port

— Sensor I/O Setting Page

When you click Sensor I/O in the menu section, the
Sensor I/O Setting page appears.
Use this page to configure the Sensor I/O port on the rear
panel of the camera.

Upper Half of Sensor I/O Setting
Page

Activity Detection (AD)

Set up the activity detection that detects movement in
the image shot by the camera.

Available Alarm Events

Select Enable if you want to output an alarm when
movement is detected, or Disable if you do not want to
output an alarm.

Scheduling

Using the boxes below, you can set up to 6 schedules on
which the activity detection works.
Select Enable to enable all the schedules whose check
boxes you have selected, or Disable to disable them.

Scheduling 1 to Scheduling 6

For each schedule, type the time in hours and minutes
when the activity detection starts and ends, and select
the check box(es) of the working days of the week.
To enable each schedule you have set, select the check
box on the left of Scheduling. You can select multiple
schedules.

Activity Detection Threshold

Select the sensitivity of activity detection: Low, Mid,
High, Super or Hyper.
The highest sensitivity is given by Hyper, which can
detect the smallest movement.

Showing Pop-up

You can set for displaying “AD” (Activity Detection)
pop-up on the lower-right of the monitor image when an
alarm output is detected.
Select On to show a pop-up, or Off not to show it.

Output 1

Set up Output 1 of the Sensor I/O port.
Output 1 can output an alarm triggered by the activity
detection or manually.

Output Status Control

Select Active to keep Output 1 of the Sensor I/O port
usually open and close it only when an alarm is output.
Select De-Active to keep Output 1 usually closed and
open it only when an alarm is ouput.

Alarm Event-Based Output Activation Function

Select AD to synchronize the output from Output 1 of
the Sensor I/O port with an alarm by the activity
detection, or Manual to output manually by clicking the
Sensor 1 button on the viewer page.

Output Active Duration Time

Type the duration of the output from Output 1 between
1 and 60 seconds.

Advertising