Configuring the Sensor I/O Port — Sensor I/O Setting Page

28

Lower Half of Sensor I/O Setting
Page

Sensor Input (SI)

Set up the sensor input, that is, the input to the Sensor I/
O port on the rear panel of the camera.

Available Alarm Events

Select Enable if you want to output an alarm when the
input to the Sensor I/O port is detected, or Disable if
you do not want to output an alarm.

Scheduling

Using the boxes below, you can set up to 6 schedules on
which the sensor input works.
Select Enable to enable all the schedules whose check
boxes you have selected, or Disable to disable them.

Scheduling 1 to Scheduling 6

For each schedule, type the time in hours and minutes
when the sensor input starts and ends, and select the
check box(es) of the working days of the week.
To enable each schedule you have set, select the check
box on the left of Scheduling. You can select multiple
schedules.

Sensor-Type Selection for Input

Select the level of the input which can be used to trigger
an alarm: Low or High.

Input Current Status

Displays the current status of the device connected to the
input of the Sensor I/O port.

Inter-alarm Event Detection Time

Type the duration, between 5 and 60 seconds, during
which the camera can detect the next alarm input.

Showing Pop-up

You can set for displaying “SI” (Sensor Input) pop-up
on the lower-right of the monitor image when an alarm
output is detected.
Select On to show a pop-up, or Off not to show it.

Output 2

Set up Output 2 of the Sensor I/O port.
Output 2 can output an alarm triggered by the sensor
input or manually.

Output Status Control

Select Active to keep Output 2 of the Sensor I/O port
usually open and close it only when an alarm is output.
Select De-Active to keep Output 2 usually closed and
open it only when an alarm is ouput.

Alarm Event-Based Output Activation Function

Select SI to synchronize the output from Output 2 of the
Sensor I/O port with an alarm by the sensor input, or
Manual to output manually by clicking the Sensor 2
button on the viewer page.

Output Active Duration Time

Type the duration of the output from Output 2 between
1 and 60 seconds.

Apply/Cancel/Help

See “Buttons common to every setting page” on page
15.