Lectrical, Pecifications – SimpleTech ZeusIOPS User Manual

Page 28

Advertising
background image

28

Zeus

IOPS

3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

E

LECTRICAL

S

PECIFICATIONS

P

OWER

S

UPPLY

The following voltage specification applies to the drive power connector. Connections to the drive
should be made in a safety extra low voltage (SELV) circuit.

The drive does not use the +5V supply input pins available on a typical 40-Pin SCA-2 connector.
The drive uses the +12V supply input. The 5V ground pins are connected to the common ground
plane within the unit.

Adequate secondary over-current protection must be incorporated in the host system (drive
enclosure, backplane, etc.). A 10 amp limit is required for safety purposes.

P

OWER

R

EQUIREMENTS

The Zeus

IOPS

3.5-inch Fibre Channel SSD requires a 12V +/-10% DC power source. If a power

failure occurs, the drive design ensures that the data contained in the storage memory is preserved.
Data loss or corruption does not occur.

Table 5.

Zeus

IOPS

3.5-Inch SSD Power Requirements

P

OWER

C

ONSUMPTION

Table 6.

Zeus

IOPS

Fibre Channel SSD Typical Power Consumption

CAUTION: To avoid damage to the drive, power

supply voltage transients must not exceed 16

volts.

Item

Requirement

Input Voltage

12V +/-10%

Minimum Voltage

10.8

Maximum Voltage

13.2

Activity

Average Current (mA)

Average Power (W)

Startup

1,200

14.4

Idle

450

5.4

Max Read @ 200MB/sec

700

8.4

Max Write @ 100MB/sec

675

8.1

Read, 1 Block Random I/O @ > 50,000

525

6.3

Write, 1 Block Random I/O @ > 18,000

660

7.9

Advertising