SimpleTech ZeusIOPS User Manual

Page 49

Advertising
background image

Zeus

IOPS

3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

49

W

RITE

B

UFFER

C

OMMAND

(3Bh)

The WRITE BUFFER command is complementary to the READ BUFFER command as a diagnostic
function for testing logical unit memory in the SCSI target device and the integrity of the service
delivery subsystem.

Table 26.

Write Buffer Command (3Bh)

The only mode fields supported are:

S

YNCHRONIZE

C

ACHE

(10) (35h)

The Logical Block Address and Number of Blocks fields are checked to ensure that the fields are in
range, but are then ignored and considered set to zero. All outstanding data is written out to the non-
volatile memory. The SYNC_NV and IMMED bits in CDB Byte 1 are ignored.

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code (3Bh)

1

Reserved

Mode

2

Buffer ID

3

(MSB)

Buffer Offset

5

(LSB)

6

(MSB)

Parameter List Length

8

(LSB)

9

Control

Mode

Value

Description

5

05h

Download microcode and save.

7

07h

Download microcode with offsets and save.

Advertising