64

Zeus

IOPS

3.5-Inch Fibre Channel Solid State Drive Product Manual Rev. 1.0

P

OWER

-O

N

F

AULT

C

ONDITIONS

The fault codes listed in Table 37 indicate that a fault has been detected during the power-on
sequence. As a result, the unit is in a non-operational state and remedial action is required to replace
the unit.

Power-on fault codes are indicated as a series of flashes. The fault light will illuminate for 0.25
seconds (250mS), then turn off for 0.25 seconds (250mS), followed by a 2 second off interval. The
number of flashes between each 2 second off period is used to indicate the different fault conditions.

Table 37.

Power-On Fault Codes

The fault code should be noted (along with the drive serial number if possible), and either the supplier
of the SSD unit or technical support should be contacted.

Flash Series

Condition

1 Flash

Memory strobe adjustment failure.

2 Flashes

Memory address failure.

3 Flashes

Memory data failure.

4 Flashes

ECC error encountered during memory test.

5 Flashes

ECC detection/correction circuit failure.