o

Minent

®

Overflow valve Sigma/ 2 liquid end, 16 bar SST

Identcode Type: 16050, 16090, 16130

Overflow valve Sigma/ 2 liquid end, 12 bar SST

Identcode Type: 12050, 12090, 12130

Overflow valve Sigma/ 2 liquid end, 7 bar SST

Identcode Type: 07120, 07220

Overflow valve Sigma/ 2 liquid end, 4 bar SST

Identcode Type: 04350

Product description S2Ba/S2Ca

Fig. 7

3161-4

IMPORTANT

• Knob item 139 must be turned in clockwise direction as far as it will go towards ”close“.

• The bypass line must always be closed and must be routed back into the supply tank.

Connection via hose connection item 128.

• Minimal overflow can occur in the bypass line when the valve operates close to the

overpressure function.

The bleeder function is achieved by turning knob item 139 in counterclockwise direction as far as
it will go towards ”open“: Priming aid for starting up pump against pressure. The force of spring
item 132 relieves ball item 130 which is controlled by the lower spring force of bleeder spring
item 133.

IMPORTANT

Once the pump has primed, turn knob item 139 in clockwise direction as far as it will go
towards ”close“! The pump is now operational.