Dulcodes UV-Desinfektionsanlage

Technical data, external contact

Semi-conductor switch elements (e.g. transistors in open-collector circuits) or contactors (relays)
with a residual voltage of -0.7 V can be used as input switch elements.

Controller type 0 (see identity code)

Pin 1 = Pause input (activating function)

Voltage at open contacts: approx. 5 V
Input resistance: 10 kΩ
Controller:

– zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)

Pin 2 = Contact input

Voltage at open contacts: approx. 5 V
Input resistance: 10 kΩ
Controller:

– zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)

Min. contact duration:

20 ms

Max. pulse frequency:

25 pulses/s

Pin 3 = unused

Pin 4 = GND

Pin 5 = Auxiliary input

Voltage at open contacts: approx. 5 V
Input resistance: 10 kΩ
Controller:

– zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)

Controller type 1 (see identity code)

Pin 1 = Pause input (activating function)

Voltage at open contacts: approx. 5 V
Input resistance: 10 kΩ
Controller:

– zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)

Pin 2 = Contact input (not active during analogue operation)

Voltage at open contacts: approx. 5 V
Input resistance: 10 kΩ
Controller:

– zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)

Min. contact duration:

20 ms

Max. pulse frequency:

25 pulses/s

Pin 3 = Identical to input*

Input load:

approx. 120 Ω

Pin 4 = GND

Pin 5 = Auxiliary input

Voltage at open contacts: approx. 5 V
Input resistance: 10 kΩ
Controller: – zero volts contact (approx. 0.5 mA)
– semi-conductor (residual voltage: < 0.7 V)

* The metering pump makes its first metering stroke at approx. 0.4 mA (4.4 mA) and starts
continuous operation at approx. 19.2 mA.

Features of the S2Ca metering pumps